-40%

Compact size Rotary paddle level sensor for powder bin detect control switch

$ 34.32

Availability: 100 in stock
  • Model: QRP-mini
  • Package Quantity: 1
  • Number of Items in Set: 1
  • MPN: RP-2020
  • Suitable For: powder
  • Color: Blue
  • Voltage: 24 V
  • Material: Steel
  • Item Height: 35cm
  • Brand: QXL
  • Manufacturer Warranty: 1 year
  • All returns accepted: ReturnsNotAccepted
  • Item Width: 12 cm
  • Condition: New
  • Manufacturer Color: Blue
  • Type: Tool Holder

    Description

    1. SPECIFICATION:
    Power source
    24VDC/110/220VAC
    Power
    1-3W
    Contact capacity
    SPDT 250VAC/ 10A
    Speed
    1 rpm
    Insulation V.
    1500V in 1 minute
    Specific gravity
    >=0.5g/cm3
    Torque
    0.3~1Nm
    2. PRINCIPLE
    A unit is usually located through a bin wall at the top, middle or low level of a bin. During normal operation (no material present) a synchronous motor rotates the paddle at 1 RPM. When this paddle rotation is impeded by material, surrounding the paddle, motor will stall and cause the Micro switch to change state. (Indicating an alarm or control)
    The torque spring is applied to adjust the output torque of the shaft, which is set at “weak” position at factory, it is adjustable for target measuring material S.G.(special gravity), if the measured material with higher S.G., please try to release it to more stronger spring force position until you found the proper orientation.   The paddle sensitivity will be interacted by weaker, otherwise, the low S.G. material will release torque spring to the weakest position, which will cause the paddle performance to be more sensitive.   Note: the torque force should not be adjusted during test, avoiding the error check signal.
    CAUTION
    Make sure the supplying voltage is same as the specifications. Wrong voltage will damage the sensor.
    WARNING
    To avoid personal injury, DO NOT remove the housing cover after supplying the power. If you will touch any solder joints and terminals, you may receive an electric shock.
    5. MAINTENANCE
    Please check that the shaft and the paddle is bended or is damaged; Please check the connect between the shaft and the paddle; Do cleaning the shaft and the paddle timely.
    6. INSTALLATION
    When do installing or maintenance, open the device only after the power source is off. Please side mount the switch by inclined 15°~20° to decrease the material inflowing impact; The wiring entry face downward, avoid the rain permeate into housing body.